Features Specifications Appliaction Download
Products Variable Frequency Drives Low Voltage Drive Application Specific Variable Frequency Drives Pumps
WP9 Series Multiple pump control
WP9 Series Multiple pump control
WP9 Series Multiple pump control

The main characteristic of the WP9 multiple pump Frequency Inverter is the control of two or more pumps in parallel using only one frequency inverter. The inverter selects which pumps will operate in order to keep/control the process value of the pumping system. An alternation between their activation is also performed, making it possible an equal use of the pumps.

Input voltage,V
Power range, кW
2200.4- 3.7
380~4800.75- 450


 



Features

The main characteristic of the WP9 multiple pump Frequency Inverter is the control of two or more pumps in parallel using only one frequency inverter. The inverter selects which pumps will operate in order to keep/control the process value of the pumping system. An alternation between their activation is also performed, making it possible an equal use of the pumps.

Main characteristics

  • Full protection for pumping systems and maximized usability through special functions

  • The ▲▼ key directly adjusts the target pressure.

  • Power off,then when the power is restored, it will automatically restart the running function.

  • Extended relay output can achieve one inverter control four constant pressure water supply pump.

  • 24VDC power supply to power the current transmitter

  • The inverter has the intelligent judgment function of dormancy.

  • English keyboard displays target value and feedback value.

  • It can be extended to 4 pumps for water supply, including stabilized pressure pump and variable frequency pump.

  • It supports the online selection function of feedback pressure gauge and current transmitter.

  • 1 pump and 1 frequency conversion linkage control completes constant pressure water supply function.

  • The keyboard can start the constant pressure water supply control function, can have the stop function and the fault reset function.

Security alarm function

  • High water pressure alarm function, low water pressure alarm function

  • Protection function of water shortage 

  • Antifreeze function;

  • Detect sensor disconnection;

  • Automatic reset function of water shortage fault

  • Multi-pump control, fault pump is manually cut off

Specifications

Item

Spetification

Standard function

Maximum frequency

V/F control:    0600.00Hz

Carrier frequency

0.5kHz12kHz

The carrier frequency is automatically adjusted   based on the load features.

Input frequency resolution

Digital setting: 0.01Hz

Analog setting: Maximum frequency ×0.025%

Control mode

Sensorless flux vector controlV/F   control

Startup torque

G type: 0.5Hz/120%

P type: 0.5Hz/100%

Speed range

1: 100

Overload capacity

G type: 60s for 150% rated current3s for   180% rated current.

P type: 60s for 120% rated current3s for   150% rated current.

Torque boost

Auto- boost

Customized boost 0.1%~30.0%

V/F curve

Straight-line V/F curve

Multi-point V/F curve

N-power V/F curve (1.2-power, 1.4-power,   1.6-power,

1.8-power, square)

V/F separation

Two types: complete separation; half separation

Ramp mode

Straight-line ramp

S-curve ramp

Four groups of acceleration/deceleration time   with the range of 0.0–6500.0s

Function

DC braking

DC braking frequency: 0.00 Hz to maximum   frequency

Braking time: 0.0–100.0s

Braking action current value: 0.0%–100.0%

JOG control

JOG frequency range: 0.00Hz~50.00Hz.

JOG acceleration/deceleration time of   0.0s~6500.0s.

Multiple preset speeds

It implements up to 16 speeds via the simple PLC   function or by input terminal states

Built-in PID

It realizes process-controlled closed loop   control system easily.

Auto voltage

regulation (AVR)

It can keep constant output voltage automatically   when the mains voltage changes.

Over-voltage/

Over-current stall

control

The current and voltage are limited automatically   during the running so as to avoid frequent tripping due to   over-voltage/over-current.

Rapid current limit

It helps avoid frequent over-current faults

Torque limit and torque control

 It can   limit the torque automatically and prevent frequent over-current tripping.